Wall-mounted split and multisplit air conditioners PURE

The Pure air conditioner delivers countless features for your comfort, timeless design and progressive smart control via the Tuya app which is at the cutting edge of smart device control.

The Pure range of air conditioners offers 4 power levels of inverter-controlled air conditioners in 2.6kW, 3.4kW, 5.1kW and 6.8kW in cooling mode and 2.8kW, 3.6kW, 5.6kW and 7kW in air-to-air heat pump mode in split operation.

In the multisplit version, 2-5 indoor units can be connected to one outdoor unit to save space and optimise costs.

The Pure units, packed with the features described below, provide comprehensive use for temperature control, air filtration, energy efficient operation and maximum variability of use in all temperature conditions.

Contact us to solve your requirement for a comfortable climate!

Wi-Fi

Manage your Giwee Pure air conditioner wherever you like! The air conditioner has a basic WiFi module that allows us to remotely set the operating temperature, turn on/off the device, change modes or set a weekly schedule for our device. Control is via the Tuya app, which can be installed on Android or iOS phones.

wifi-control
plasma

Plasma filtration

Plasma filtration ensures the elimination of dust particles, pollen and smoke and, unlike other types of filtration, the elimination of bacteria and viruses.

Silent mode

With a 19dB(A) rating, Pure air conditioners are the quietest units on the market and ensure an undisturbed sleep. The minimum fan speed and frequency limitation of the outdoor air conditioning unit for night operation will exceed your expectations.

silence mode

Compatible with multisplit

Pure wall units are compatible with split 1:1 and multisplit 1:2, 1:3, 1:4, 1:5 units. You can enjoy the benefits and features it brings in all versions!

sleep-mode

Sleep mode

Minimum speed for undisturbed sleep, automatic temperature increase for cooling and decrease for heating for 7 hours

turbo-mode

Turbo Mode

Large wind, Reach the set temperature quickly, fast cooling & Heating

auto-mode

Auto mode

The air conditioner will auto run different modes according to the difference between the room temperature and the set temperature

i-feel-function

I FEEL function

The room temperature probe can be set on the remote controller through the I FEEL function, so it detects the room temperature of the remote controller locates

anti-cold-wind

Anti-cold wind

This limits the fan from blowing colder air when in heating mode thus preventing cold drafts

vertical-swing

Vertical swing

The outer louver swings vertically to adjust the air supply angle in the vertical direction

horizontal-swing

Horizontal swing

The inner louver swings horizontally to adjust the air supply angle in the horizontal direction

wifi-control

WIFI control

Remote WIFI control the air conditioner even when you are far away from it

silence-mode

Silence mode

The AC fan is adjusted to the lowest wind to reduce the indoor noise to 19dB(A) and compressor frequency is fixed at low frequency

Plasma filter

Plasma filter

Build in plamsa generator produces plasma, sterilize and remove dust, purify the air and benefit your health

self-cleaning

Self-cleaning

When self clean function is activated, the indoor coil dries itself using a 3-stage cycle that minimises the accumulated dust and mould

heating-at-15

Heating at -15°C

Achieve stable heating at -15 degrees low temperature

rapid-cooling-heating

Rapid cooling & Rapid heating

It takes only 30 seconds for the cooling air temperature to drop from 27°C to 18°C, and only 60 seconds for the heating air temperature to increase from °C to °C

do-not-disturb

Do not disturb

One button to turns off the indoor unit beep and LED display, the wind speed is adjusted to low, and the LED light panel is only displayed for 10 seconds each time in the do not disturb mode

24h-timer

24h timer

The system can be preset to automatically start and stop within 24Hour period

cooling-at-15

Cooing at -15°C

With built-in low ambient kit and a specially designed PCB, the outdoor fan speed is automatically changed according to the condensing temperature, cooling at -15°C available

smart-air-supply

Smart air supply

In the cooling mode, the angle of the louver is fixed upward, and in the heating mode, the angle of the louver is fixed downward

eco-mode

ECO mode

By pressing this button the system will run into an power saving mode to save money

celsius-fahrenheit-switch

Celsius & Fahrenheit switch

Convert Fahrenheit and Celsius temperature display to each other via wireless controller

cooling-at-48

Cooling at 48°C

Using refrigerant pipeline cooling technology to cool down the electronic control to achieve stable cooling in a 48°C high-temperature environment

1w-standby

1W stand-by

Turn off the power of ODU after 2 minutes in the shutdown state, and disconnect the power of ODU at air supply mode for 2 minutes for power saving

golden-fin

Golden Fin

Golden fin of indoor and outdoor units are customizable for better appearance and Anti-corrosion performance

child-lock

Child lock

Button lock function prevents children from accidentally pressing the remote controller

auto-restart

Auto restart

If the system is stopped because of power failure, it will auto restart in the previous settings and mode when the power is back

self-diagnosis

Self diagnosis

If the failure happens, the error code will be displayed on the panel,you can also check the status by remote controller

low-voltage-operation

Low voltage operation

172V low voltage operation

fireproof

Fireproof E-box

The E-box is made of high fireproof level material,fully meet the safty regulations for the safe operation

room-card-function

Room card function

Specialised built in reserved room cards ports, which allows a remote ON/OFF switch to be easily connected

emergency-button

Emergency button

If a temperature sensor error occurs the unit will alarm and operate in emergency function mode until replaced

dual-drainage

Dual drainage

Two drainage holes are reserved,you can install drainage pipe left or right according to different project requirements

louver-position-memory

Louver position memory

The indoor unit will remember the louver position at the time it was turned off. It will set the louver to the same position again when it is reinitialised

error-alarm-output

Error Alarm Output

When failure happens,the system will sent a message to designated terminal receiving equipment

basepan-heater

Basepan heater

The chassis is heated to prevent the running fan blade damaged by the accumulated snow in winter

wider-controller

Wired controller

Controller board of indoor unit reserves the wired controller port, the air conditioner can be controlled by wired controller